Power outages & repairs
Lost power? Let’s find out why, today.
A breaker that won’t stay on, a row of dead outlets, lights that dim every time the AC starts. We test until we find the actual fault, tell you what it is in plain words, and fix it. When it can’t wait, we’ll get an electrician to you ASAP.

- Median LA home 1965 year built, City of LA (ACS)
- GFCI trips at ~5mA of current leaking to ground
- Smoke alarms 10yrs then replace the whole unit
Call us when
-
01
The breaker trips when the AC runs
An overloaded circuit, a weak breaker or a compressor pulling too hard at start-up. -
02
Half the house has no power
Often a lost leg of the service or a failing main breaker, not a tripped circuit. -
03
Outlets are dead but no breaker is off
Usually a tripped GFCI in another room or a loose connection upstream. -
04
Lights flicker or dim
One fixture is a bulb or a switch. The whole house is a connection worth finding today. -
05
A GFCI won’t reset
It may be doing its job on a real fault, or the outlet itself has failed. -
06
Burning smell or a warm panel
Don’t wait on this one. See below.
Burning smell, a warm panel or a buzzing breaker
If it’s safe to reach, switch off the main breaker at the panel, then call us. Don’t reset a breaker that keeps tripping and don’t keep using an outlet that feels hot or smells scorched. If you see smoke or flame, get everyone out and call 911 first.
Heat at a panel or an outlet means a connection is failing, and it gets worse every time current runs through it. Tell us that first when you call. More on what a burning smell at the panel means.
How we troubleshoot
Resetting breakers until one holds isn’t a diagnosis. We test the circuit: voltage at the outlets, the load on the breaker, the connections in the boxes and at the panel. When we know the cause, we tell you what it is and what the fix costs, then do the work.
- Breaker trips with the AC. We check whether the circuit, the breaker or the panel is the limit. Sometimes it needs a dedicated circuit, sometimes a new breaker.
- Half the house out. If the neighbours have power and a 240-volt appliance like the dryer won’t run, one leg of the service may be down. That can be on LADWP’s side, and we’ll tell you if it is. See why half the house loses power.
- Dead outlets, breaker on. A tripped GFCI in a bathroom or the garage often feeds outlets in other rooms. If it isn’t that, we trace the loose connection.
- Flickering. We find out whether it’s the fixture, the dimmer, the circuit or the service feeding the whole house. See why lights flicker.
- GFCI and AFCI. GFCIs guard against shock in wet areas. AFCIs catch arcing in bedroom and living-area circuits. Both can trip for a real reason, so we find it before swapping a device.
Surge protection, smoke and CO alarms
Some repairs are about what happens next time. A whole-house surge protector mounts at the panel and takes the hit before it reaches the fridge, the AC board and the TV. Current code calls for one whenever a service is replaced or upgraded, and it can be added to an existing panel too.
Smoke alarms wear out: replace the unit every 10 years, not just the battery. California also wants carbon monoxide alarms outside sleeping areas and on every level in homes with gas appliances, a fireplace or an attached garage. We install hardwired, interconnected alarms so one going off sets off the rest.
The process
How a repair call runs
-
The call
Tell us what happened
What went off, what you were running at the time, and a photo of the panel if you can.
-
On site
Find the fault
We test the circuit and the panel until we know the cause, not a guess.
-
Before work
Price for the fix
You hear what’s wrong and what the fix costs. Nothing starts until you say yes.
-
Repair
Fix and test
We make the repair and test the circuit under load before we leave.
-
If it’s bigger
A plan, not a patch
If the panel or the wiring is the real problem, you get a written price for that separately.
Common questions
Why does my breaker trip when the AC turns on?
An air conditioner pulls a surge of current for a second or two as the compressor starts. If the circuit is shared, undersized or the breaker is worn, that surge is enough to trip it. Sometimes the fix is a new breaker, sometimes a dedicated circuit, and now and then the AC itself is the problem. We test before we replace anything.
Why does half my house have no power?
Most houses get power on two legs, and each leg feeds about half the circuits. If one leg drops, at the main breaker, the meter or LADWP’s line, half the house goes dark and 240-volt appliances stop. Check whether the neighbours are out too. If they aren’t, call us. If the problem is on the utility side, we’ll tell you and you call LADWP.
My outlets are dead but no breaker is tripped. What now?
Look for a GFCI outlet with test and reset buttons, in a bathroom, the kitchen, the garage or outside, and press reset. One GFCI can protect outlets in other rooms. If that doesn’t bring them back, there’s likely a loose connection in one of the boxes, which is worth fixing before it heats up.
What should I do if I smell burning near the panel?
If you can reach the panel safely, switch off the main breaker, then call us. Don’t touch a panel that is hot, sparking or wet. If there is smoke or flame, leave the house and call 911.
Do I need a whole-house surge protector?
If the house has anything with a circuit board, from the AC to the fridge, it’s worth having. Current code calls for one whenever a service is replaced or upgraded, and one can be added to most existing panels without changing anything else.
Where do smoke and CO alarms have to go?
Smoke alarms go in every bedroom, outside each sleeping area and on every level. Carbon monoxide alarms go outside sleeping areas and on every level in homes with gas appliances, a fireplace or an attached garage. Hardwired, interconnected alarms are the better setup: when one goes off, they all do.
What moves the price
- How long it takes to find the fault. Intermittent problems take longer
- Whether the fix is a device, a breaker or a run of wire
- Access: attic, crawl space, or a wall that has to be opened
- Parts like AFCI breakers, surge protectors or hardwired alarms
- Whether the repair needs a permit and inspection
Often done together
Same-day visits
Power acting up? Call before it gets worse.
Tell us what went off and what was running. A photo of the panel helps us bring the right parts.
(888) 367-6906Open 24 hours, Sunday to Friday
- We answer right away.
- An electrician out the same day.
- The price before any work starts.
- We handle permits and paperwork.
- Photos? WhatsApp (818) 826-9904